SUMMARY:Influence of the number of sensors in the modal parameter estimat
 ion and damage detection using Operational Modal Analysis
LOCATION:Room F102
DESCRIPTION:MS 14\n\nPresenter: Fernández Ordóñez\, Guillermo\n\nAuthors:
  Fernández Ordóñez\, Guillermo\; Peláez Rodríguez\, César\; Iglesias Por
 domingo\, Álvaro\; Magdaleno\, Álvaro\; Lorenzana\, Antolin\n\nChair: Pa
 padimitriou\, Costas\n\nAbstract: Structural Health Monitoring (SHM) bas
 ed on dynamic techniques relies on accurate identification of modal para
 meters to assess structural integrity. This study investigates the impac
 t of the number of sensors on the estimation of natural frequencies\, da
 mping ratios and mode shapes\, as well as on the ability to detect damag
 e. The experimental work is conducted on a four-story laboratory-scale s
 hear building model. Damage is introduced in a controlled manner by vary
 ing the mass of each floor slab\, simulating changes in service conditio
 ns. Operational Modal Analysis (OMA) under ambient excitation is employe
 d to identify modal parameters across different scenarios and sensor con
 figurations. Several layouts are considered to evaluate how reducing the
  number of sensors affects both modal identification accuracy and sensit
 ivity to structural changes. Results indicate that natural frequencies r
 emain relatively robust under sparse instrumentation\, whereas mode shap
 es and damping ratio estimations degrade significantly\, impacting the e
 ffectiveness of damage indices based on modal correlation. This work pro
 vides practical guidelines for optimizing structural monitoring systems\
 , balancing cost and reliability. The results are promising for real-wor
 ld applications where full instrumentation is often impractical\, such a
 s bridges\, buildings and wind towers. Furthermore\, implications for pr
 edictive maintenance strategies and the deployment of SHM systems in con
 strained environments are discussed.