SUMMARY:Singular Spectrum Analysis for Structural Damage Detection in an 
 Electricity Pylon
LOCATION:Room A310
DESCRIPTION:MS 15\n\nPresenter: Lopez-Caballero\, Fernando\n\nAuthors: Qu
 intero\, Julieth\; Lopez-Caballero\, Fernando\; Gatti\, Filippo\n\nChair
 : Lopez-Caballero\, Fernando\n\nAbstract: Understanding the dynamic beha
 vior of electricity pylons is essential for evaluating the integrity and
  resilience of their foundations\, particularly under environmental load
 ing and long-term degradation. Within the framework of the HEAT-COFFEE p
 roject\, this study explores the use of Multi-channel Singular Spectrum 
 Analysis (MSSA) as a non-invasive numerical tool for detecting structura
 l damage in a finite element model of an electricity pylon. A coupled so
 il–structure model of the pylon was developed in Code_Aster\, where the 
 system was subjected to ambient noise excitation to reproduce realistic 
 vibration conditions. The recorded responses at multiple points of the s
 tructure and foundation were processed using MSSA to extract dominant mo
 des\, study signal correlations\, and reconstruct the dynamic response. 
 Simulated damage was introduced by reducing the stiffness of selected el
 ements\, both in the pylon and in the surrounding soil\, to evaluate the
  sensitivity of the method. The results show that\, while the dominant f
 requencies remain nearly constant\, subtle variations can be observed in
  the spectral content of the reconstructed components when structural da
 mage is introduced. These variations are localized and depend on the mea
 surement position along the structure. In contrast\, the soil-damaged co
 nfiguration remains largely indistinguishable from the healthy case. The
 se findings indicate that MSSA can help capture subtle alterations in dy
 namic behavior caused by localized stiffness degradation.  The study hig
 hlights the potential of MSSA as a vibration-based technique for non-inv
 asive monitoring of large lattice structures and their foundations\, pro
 viding a promising step toward ambient vibration–based damage detection 
 in electricity pylons.