SUMMARY:Damage Detection Using Identified Uncertain Modal Parameters from
  Operational Modal Analysis
LOCATION:Room A310
DESCRIPTION:MS 15\n\nPresenter: Dubey\, Ayush\n\nAuthors: Dubey\, Ayush\;
  Ghosh\, Dhiraj\; Gaur\, Astha\; Mukhopadhyay\, Suparno\n\nChair: Lopez-
 Caballero\, Fernando\n\nAbstract: Modal parameters identified from vibra
 tion responses under operational conditions inherently involve uncertain
 ties due to measurement noise\, inputs\, and varying operational conditi
 ons. Hence\, damage detection using such identified modal parameters sho
 uld adopt a statistical framework that incorporates such uncertainties. 
 This study develops a statistical approach to detect structural damage u
 sing the Damage Locating Vector (DLV) method. The uncertainty in modal p
 arameters may be obtained either through multiple test datasets or from 
 a single dataset using appropriate modal identification techniques. Usin
 g a single dataset\, the uncertainty of the identified modal parameters 
 is propagated using first order Taylor series expansion to compute the m
 ean and variance of the cumulative stress (CS) obtained using DLV. The c
 omputed CS is then compared with that of baseline (undamaged) condition 
 using Mahalanobis squared distance to identify the location of damage. I
 f multiple baseline datasets are available\, the probability distributio
 ns of Normalized Cumulative Stresses (NCS) in different structural eleme
 nts can be obtained using DLV. The NCS distributions obtained for the cu
 rrent state of the structure are then compared with those obtained from 
 a baseline state using the Jensen–Shannon divergence\, based on which th
 e structural element may be detected to be in same condition as baseline
  or damage. The method is validated using two examples. The first exampl
 e is a continuous bridge under moving heavy train load\, with the variab
 ility in the identified modal parameters induced by time-varying nature 
 of the train-bridge system. In the second example\, a laboratory scale s
 teel frame is subjected to a suite of base excitations\, where the uncer
 tainty in the identified modal parameters is induced by the uncertainty 
 in the applied base excitations applied through shaking table. It is see
 n that\, in both the examples\, the methods could correctly detect the d
 amaged structural elements.