SUMMARY:Port-Hamiltonian Structural Consistency Residual Damage Detection
  in Discrete Timoshenko Beams
LOCATION:Room A310
DESCRIPTION:MS 15\n\nPresenter: Esquivel-Sancho\, Luis\n\nAuthors: Esquiv
 el-Sancho\, Luis\; GhandchiTehrani\, Maryam\; Muñoz-Arias\, Mauricio\n\n
 Chair: Lopez-Caballero\, Fernando\n\nAbstract: Structural damage detecti
 on in flexible beam structures requires methods that combine physical in
 terpretability with fault localization. This paper proposes an energy-ba
 sed framework for damage detection\, localization\, and severity estimat
 ion in discrete Timoshenko cantilever beams\, grounded in port-Hamiltoni
 an system theory. The beam is formulated in explicit port-Hamiltonian fo
 rm using finite elements\, HRZ mass lumping\, and Rayleigh proportional 
 damping. The central contribution is the port-Hamiltonian Structural Con
 sistency Residual\, a power-balance violation metric that decomposes ana
 lytically into element-level damage signatures\, enabling localization t
 hrough a matched-filter least-squares estimator without prior knowledge 
 of damage location or magnitude. The framework is validated numerically 
 on a cantilever beam across four configurations (uniform and non-uniform
  cross-section\, each with 0% and 1% measurement noise) and fifty ideali
 zed stiffness-loss damage scenarios per configuration (10 elements × 5 s
 everity levels\, 2–30% stiffness reduction). Overall localization accura
 cy ranges from 86% (uniform\, noiseless) to 66% (non-uniform\, 1% noise)
 \, with exact identification reaching 100% at 30% severity for mid-span 
 elements across all configurations.