SUMMARY:Multi-Objective Optimization of a Viscoelastic-Hysteretic Device 
 for Vibration Mitigation in Two Coupled Oscillators
LOCATION:Room F107
DESCRIPTION:MS 17\n\nPresenter: Potenza\, Francesco\n\nAuthors: Potenza\,
  Francesco\; Pierantozzi\, Mariano\; Vasta\, Marcello\; Gattulli\, Vince
 nzo\n\nChair: Gattulli\, Vincenzo\n\nAbstract: Dissipative coupling repr
 esents an efficient strategy to protect dynamically excited structures f
 rom damage while enhancing their resilience. However\, selecting the opt
 imal properties of the damping device remains challenging due to the nee
 d to balance conflicting objectives\, such as minimizing displacements a
 nd accelerations. This study presents a simplified procedure for the pre
 liminary design of an optimal viscoelastic-hysteretic damper coupling tw
 o simple oscillators. The optimization relies on the nonlinear stochasti
 c response of the system - quantified through the standard deviations of
  displacements and accelerations - evaluated via equivalent linearizatio
 n. The problem is formulated as a two-step multi-objective optimization.
  In the first step\, Pareto fronts are derived to identify non-dominant 
 solutions representing the trade-off between displacements and accelerat
 ions under low (serviceability) and high (safety) levels of white noise 
 excitation. In the second step\, a multi-objective metaheuristic algorit
 hm is employed to determine the optimal damper configuration based on th
 e outcomes obtained from the first step. The results are compared with t
 raditional approaches\, demonstrating the potential and effectiveness of
  the proposed procedure.