BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//EURODYN//Schedule//DE
CALSCALE:GREGORIAN
METHOD:PUBLISH
BEGIN:VTIMEZONE
TZID:Europe/Berlin
X-LIC-LOCATION:Europe/Berlin
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:19700329T020000
RRULE:FREQ=YEARLY;BYMONTH=3;BYDAY=-1SU
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:19701025T030000
RRULE:FREQ=YEARLY;BYMONTH=10;BYDAY=-1SU
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
UID:619@eurodyn2026.org
DTSTAMP:20261026T144037Z
DTSTART;TZID=Europe/Berlin:20260930T142000
DTEND;TZID=Europe/Berlin:20260930T144000
SUMMARY:Mitigating Seismic Pounding in L-Shaped Adjacent Steel Buildings 
 Using Bracing Systems
LOCATION:Room B302
DESCRIPTION:MS 09\n\nPresenter: Hussein\, Mohamed\n\nAuthors: Hussein\, M
 ohamed\n\nChair: Fischer\, Cyril\n\nAbstract: L-shaped buildings are par
 ticularly vulnerable to seismic actions due to their inherent geometric 
 irregularity\, which leads to uneven stiffness distribution and complex 
 dynamic behaviour. When such buildings are located close together\, the 
 risk of seismic pounding increases significantly\, potentially causing l
 ocal damage\, amplifying inter-storey drift\, and leading to progressive
  structural deterioration. This study investigates the effectiveness of 
 bracing systems in mitigating seismic pounding between adjacent L-shaped
  steel buildings. A nonlinear time-history analysis framework was develo
 ped to assess the structural response to three representative earthquake
  records (Ko-be\, Chi-Chi\, and Northridge). Three bracing configuration
 s\, namely X-\, V-\, and inverted V-bracing\, were examined. The results
  indicate that bracing systems can significantly influence the distribut
 ion of seismic response rather than simply reducing it. While back-side 
 bracing effectively suppresses pounding at the rear interface\, it may s
 hift the critical interaction to the front side. Among the configuration
 s examined\, X-bracing and inverted V-bracing provide more balanced perf
 ormance in controlling both displacement and inter-storey drift\, wherea
 s V-bracing shows less consistent behaviour\, despite reducing base shea
 r in some cases. Overall\, the findings demonstrate that seismic poundin
 g mitigation in adjacent irregular buildings is governed by a complex in
 terplay between stiffness modification and load redistribution. Therefor
 e\, the effectiveness of bracing systems cannot be assessed using a sing
 le performance indicator and requires a multi-criteria evaluation.
URL:https://eurodyn2026.org/submission/619
END:VEVENT
END:VCALENDAR