  Variable Inertia
LOCATION:Room B302
DESCRIPTION:MS 09\n\nPresenter: Wierschem\, Nicholas\n\nAuthors: Cupp\, W
 yatt\; Wierschem\, Nicholas\n\nChair: Fischer\, Cyril\n\nAbstract: The c
 lutching inerter damper (CID) is a passive nonlinear structural control 
 device that converts translational motion into the rotational motion of 
 flywheels\, but unlike inerters features one-way clutching mechanisms th
 at prevent energy introduced into the flywheel from being transferred ba
 ck to the main structure. While the CID can have many positive impacts o
 n the dynamic performance of the structures they are attached to\, the i
 nstantaneous increase in the structure’s effective mass that occurs with
  the engagement of the CID can unfavorably impact its performance at hig
 h frequencies. This work examines a novel nonlinear mechanism called the
  clutching inerter damper with variable inertia (CIDVI). The CIDVI incor
 porates flywheels with passively variable inertia to soften the impact o
 f engagement of the device. In this work\, the CIDVI is formulated and n
 umerically investigated. The CIDVI’s behavior and performance is studied
  by examining the response of a structure with either a CID or CIDVI und
 er a variety of loading conditions. Because of its variable inertance\, 
 the CIDVI was able to dissipate its rotational energy more effectively t
 han the CID and reengage with the structure more often than the CID. The
  performance of the CIDVI was shown to depend on the excitation amplitud
 e\; however\, in many cases\, the CIDVI was able to reduce the high freq
 uency acceleration responses and force transfer otherwise seen with a co
 mparable CID.