SUMMARY:System Identification and Long-Term Modal Tracking of an Earthqua
 ke-Damaged Masonry Bell Tower
LOCATION:Room F303
DESCRIPTION:MS 11\n\nPresenter: Civera\, Marco\n\nAuthors: Scussolini\, L
 inda\; Miraglia\, Gaetano\; Crocetti\, Alessio\; Civera\, Marco\; Ceravo
 lo\, Rosario\n\nChair: Clementi\, Francesco\n\nAbstract: The vibration-b
 ased assessment of historical masonry towers increasingly relies on oper
 ational modal analysis (OMA) and long-term tracking tools capable of dis
 tinguishing genuine structural changes from environmental and operationa
 l variability. In this work\, a 14th-century masonry bell tower in Fossa
 no (Italy) serves as a full-scale benchmark for system identification an
 d modal tracking methodologies. The key characteristic of the case study
  lies in its current structural condition: the structure was severely cr
 acked by an 1887 earthquake and\, later in recent times (2012)\, subject
 ed to provisional hooping. Following insights from a previous (2011) amb
 ient vibration test (AVT) campaign using a dense sensor layout\, a reduc
 ed permanent setup was established in 2024 for continuous\, persistent m
 onitoring. Subspace-based identification allowed the extraction of stabl
 e modal parameters despite sparse sensing\, with notable economic and pr
 actical improvements. The comparison between the recent identifications 
 and 2011 results shows a statistically significant increase in natural f
 requencies (up to ~10%)\, attributable to the 2012 tie-rod confinement s
 ystem rather than environmental effects.  Modal tracking over several mo
 nths in the last year confirmed narrow-band frequency fluctuations\, mos
 tly dominated by temperature variability\, while preserving clear detect
 ability of stiffness-related shifts. Damping ratios remained too dispers
 ive to serve as reliable indicators\, reinforcing the importance of robu
 st natural frequency-based tracking strategies. These recent results hig
 hlight how AVT-informed modal tracking can support seismic assessment an
 d upgrade design in heritage towers\, enabling three important outcomes:
  (i) quantification of positive effects from already-deployed structural
  intervention\, (ii) early detection of anomalies\, and (iii) evidence-b
 ased comparison of different strengthening strategies.
URL:https://eurodyn2026.org/submission/500