SUMMARY:Vibration-based Damage Detection in Historic Quay Walls: A Full-S
 cale Test in Amsterdam
LOCATION:Room F303
DESCRIPTION:MS 11\n\nPresenter: Luca Viale\n\nAuthors: ter Meulen\, Daan\
 ; Cabboi\, Alessandro\; Peters\, Dirk Jan\; Bassitt\, James\; Brownjohn\
 , James\; Antonini\, Alessandro\; Viale\, Luca\n\nChair: Clementi\, Fran
 cesco\n\nAbstract: In the Netherlands\, more than 1700 km of historic qu
 ay walls exist. Many of those structures\, which consist of a masonry wa
 ll\, a timber floor\, timber beams\, and timber piles\, are approaching 
 the end of their service life. In order to prevent future failures (such
  as the collapse of the Grimburgwal)\, it is essential to assess their s
 tructural condition.   In this research\, a vibration-based monitoring c
 ampaign was conducted to investigate whether vibration-based monitoring 
 can be applied to assess the condition of quay wall structures. During t
 he experiment\, controlled structural damage was imposed on a quay wall 
 along the Nieuwe Herengracht in Amsterdam (constructed in 1861) by isola
 ting a segment of the structure and sequentially cutting part of its tim
 ber foundation piles. Imposing controlled structural damage to this quay
  wall was feasible\, as the Municipality of Amsterdam started the renewa
 l of this quay wall immediately after the experiment.  Acceleration meas
 urements\, complemented by inclinometer data and total-station displacem
 ent measurements\, were collected to identify and compare the dynamic fe
 atures of the structure (i.e.\, natural frequencies\, mode shapes\, and 
 damping ratios) before and after isolating the section\, as well as befo
 re and after cutting part of the timber foundation piles. Based on this 
 comparison\, this study will show whether vibration-based monitoring can
  detect variations in the quay wall's dynamic behaviour due to damage (i
 .e.\, common quay wall failure mechanisms induced during the experiment)
  and whether this information can be used as a proxy for structural heal
 th assessment.