SUMMARY:Performance Assessment of an Active Tuned Inerter Damper (ATID) S
 ystem on SDOF Structures using PID Control
LOCATION:Room B305
DESCRIPTION:MS 05\n\nPresenter: Ozsoy\, Muhammet\n\nAuthors: Olowookere\,
  Oluwaferanmi\; Dogan\, Hakan\; Ozsoy\, Muhammet\n\nChair: Mencik\, Jean
 -Mathieu\n\nAbstract: Active Tuned Mass Damper (ATMD) have been frequent
 ly studied as an effective approach for vibration mitigation\, particula
 rly for building seismic applications. Their performance\, however\, is 
 often limited by the practically achievable mass ratio. This study intro
 duces\, for the first time\, an Active Tuned Inerter Damper (ATID) syste
 m that incorporates an inerter with active control. By generating a larg
 e apparent mass relative to its small physical size\, the inerter enable
 s enhanced dynamic performance without increasing the physical mass. The
  ATID consists of a Tuned Inerter Damper (TID)\, composed of an inerter\
 , spring\, and damper\, combined with an actuator to provide active cont
 rol action.  The proposed concept is investigated through numerical anal
 ysis on a single-degree-of-freedom (SDOF) system. The passive parameters
  of the TID are optimally tuned using closed-form relations equivalent t
 o Den Hartog’s fixed-point approach\, and a proportional–integral–deriva
 tive (PID) controller is designed to minimize the structural displacemen
 t response under external excitation. The results show that the ATID pro
 vides superior vibration suppression compared with ATMD systems.