BEGIN:VEVENT
UID:78@eurodyn2026.org
DTSTAMP:20261026T144037Z
DTSTART;TZID=Europe/Berlin:20260929T175000
DTEND;TZID=Europe/Berlin:20260929T181000
SUMMARY:SSI identification and GA-based linear calibration of the isolati
 on stiffness of an FPS-isolated school building: verification on synthet
 ic ambient-like data
LOCATION:Room F102
DESCRIPTION:MS 15\n\nPresenter: Fabbretti\, Livia\n\nAuthors: Fabbretti\,
  Livia\; Stoura\, Charikleia\; Chatzi\, Eleni\; Ubertini\, Filippo\; Bre
 ccolotti\, Marco\n\nChair: Lombaert\, Geert \n\nAbstract: Seismic isolat
 ion is widely adopted to protect buildings and critical facilities by de
 coupling their response from ground motion and concentrating nonlinear e
 nergy dissipation within the isolation layer. Friction pendulum systems 
 (FPS) provide self-centering and energy dissipation capabilities governe
 d by a small set of uncertain mechanical parameters. A previous parametr
 ic study by the authors on the same FPS isolated school building showed 
 that the high speed friction coefficient is the dominant nonlinear param
 eter\, whereas the linear stiffness is the only parameter with a signifi
 cant influence in the linear regime. A subsequent work introduced a two 
 tier framework for nonlinear identification of friction parameters\, bas
 ed on a detailed three dimensional finite element model (FEM) and a cond
 ensed low order representation. However\, this framework explicitly assu
 med that the linear stiffness properties of the isolation system had alr
 eady been calibrated from ambient-vibration data. This paper addresses t
 his missing step by presenting a preliminary procedure that combines sto
 chastic subspace identification (SSI) of synthetic ambient-like vibratio
 ns with genetic-algorithm-based model updating of the isolation stiffnes
 s on the full finite element model. The genetic algorithm (GA) treats th
 e model as a black box\, updates the family-wise stiffnesses of the four
  FPS device types\, and minimizes a cost function based on discrepancies
  in the first ten natural frequencies and the corresponding mode shapes\
 , all condensed onto eight monitored horizontal degrees of freedom. Nume
 rical results on synthetic data show that the proposed identification te
 chnique can define an updated model that reproduces the target modal pro
 perties with small frequency errors and high mode-shape correlation acro
 ss these ten modes. This confirms that the linear stiffness of the isola
 tors can be consistently recovered. The study paves the way for applying
  the same procedure to real structures\, starting from the school buildi
 ng considered here\, for which continuous monitoring data are already av
 ailable.
URL:https://eurodyn2026.org/submission/78
END:VEVENT