SUMMARY:Operational Modal Analysis of a Heritage Masonry Building in Napl
 es
LOCATION:Room F303
DESCRIPTION:MS 11\n\nPresenter: Kheirollahi Dehkharghani\, Mohammad\n\nAu
 thors: Kheirollahi Dehkharghani\, Mohammad\; Zizi\, Mattia\; Pantò\, Bar
 tolomeo\; De Matteis\, Gianfranco\; Madonna\, Raniero\; Chisari\, Corrad
 o\n\nChair: Mendes\, Nuno\n\nAbstract: This study investigates the dynam
 ic behaviour of the former military hospital\, a heritage masonry buildi
 ng located in Naples\, Italy. Ambient Vibration testing (AVT) coupled to
  Operational Modal Analysis (OMA) represents a powerful experimental met
 hodology for the structural assessment of masonry constructions\, as it 
 enables the calibration of numerical models and\, in some cases\, the id
 entification of potential damage states. Nevertheless\, its practical im
 plementation on masonry heritage is often constrained by the limitations
  of conventional experimental setups\, especially in the case of large b
 uildings and a limited number of available sensors. In this research\, m
 ulti-setup ambient vibration testing is complemented by non-destructive 
 sonic tests to capture the dynamic response of the structure and the mas
 onry material parameters.  The corresponding modal parameters (namely\, 
 natural frequencies and mode shapes) are estimated from the recorded vib
 ration data through Frequency Domain Decomposition (FDD) and used to cal
 ibrate a finite element model of the building through a model updating a
 nalysis. The adopted methodology allowed for a strong correlation betwee
 n the experimental and numerical dynamic properties. The findings provid
 ed a comprehensive understanding of the building’s seismic behaviour and
  potential vulnerabilities\, thereby establishing a robust analytical ba
 sis for assessing the building's vulnerability against natural events an
 d implementing effective retrofitting and preservation strategies for he
 ritage masonry buildings.