BEGIN:VEVENT
UID:600@eurodyn2026.org
DTSTAMP:20261026T144037Z
DTSTART;TZID=Europe/Berlin:20260929T171000
DTEND;TZID=Europe/Berlin:20260929T173000
SUMMARY:Resilience-Based Wind Assessment of Archetypal Tall Reinforced-Co
 ncrete Buildings in India
LOCATION:Room A310
DESCRIPTION:MS 19\n\nPresenter: Zelelew\, Endegena Ayalew\n\nAuthors: Zel
 elew\, Endegena Ayalew\; Scarapazzi\, Chiara\; Mall\, Morewe\; Hussain\,
  Baseer\; Vijendran\, Vasavi\; Panchal\, Aniket\; Athanasiou\, Anastasia
 \n\nChair: Denoël\, Vincent\n\nAbstract: Traditional prescriptive wind d
 esign requires the Main Wind Force Resisting System (MWFRS) to stay elas
 tic\, conflicting with performance-based seismic approaches. The new ASC
 E Pre-standard for performance-based wind design introduces limit states
  allowing controlled nonlinearity in the MWFRS above the elastic limit. 
 This supports wind resilience moving past structural safety to include s
 erviceability\, functionality\, and recovery after extreme wind events. 
 This study investigates the wind performance of two archetypal 25-storey
  RC office buildings representative of modern tall structures on the Ind
 ian west coast\, a region characterised by high basic wind speed of 50 m
 /s. The buildings\, designed according to IS875\, are doubly symmetric i
 n plan and regular in elevation and consist of a dual system of shear wa
 lls and moment-resisting frames. One building is on a site with a 0.24g 
 PGA\, making its design earthquake-governed\, while the other is on a 0.
 16g PGA site\, leading to its design being wind-governed. Detailed 3D mo
 dels are developed in SAP2000\, and the buildings are subjected to suite
 s of wind tunnel-derived alongwind and crosswind excitations. Wind IDAs 
 are performed to determine their response at and beyond the design level
 . Performance objectives and acceptance criteria for wind are mapped to 
 admissible damage states\, defined according to the ASCE Pre-standard. T
 he resilience of the buildings is evaluated adopting the FEMA P-58 metho
 dology and its PACT tool for wind to estimate probabilistic damage\, fun
 ctionality loss\, and recovery time. The study concludes by discussing t
 he implications of prescriptive design on actual wind performance and de
 monstrating the potential benefits of performance-based approaches for t
 all buildings in high-wind regions\, while contributing to the broader d
 iscourse on wind resilience through considerations of serviceability\, f
 unctionality\, and recovery capacity.