SUMMARY:Vibration-based global long-term monitoring of the Maintalbrücke 
 Gemünden using SSDD and numerical FE simulations
LOCATION:Room F102
DESCRIPTION:MS 14\n\nPresenter: Herrmann\, Ralf\n\nAuthors: Hille\, Falk\
 ; Simon\, Patrick\; Herrmann\, Ralf\; Baeßler\, Matthias\n\nChair: Papad
 imitriou\, Costas\n\nAbstract: This contribution presents the implementa
 tion and evaluation of vibration-based structural health monitoring on t
 he Maintalbrücke Gemünden\, a semi-integral 299-meter-long reinforced co
 ncrete frame bridge located along the high-speed railway between Hannove
 r and Würzburg in Germany. The monitoring concept is based on the Stocha
 stic Subspace-based Damage Detection (SSDD) method\, facilitating long-t
 erm and global surveillance of the load-carrying structure. Ambient vibr
 ation measurements are continuously recorded\, supplemented by controlle
 d load tests\, to capture structural changes over time\, including the e
 ffects of environmental factors such as temperature. To complement the b
 ridge's real-world monitoring\, a detailed finite element (FE) model of 
 the structure was developed. Numerical SSDD analyses on this model enabl
 e investigation of potential causes for observed changes in the bridge’s
  global dynamic response. By simulating different scenarios and adjustin
 g model parameters\, it is possible to assess the influence of damage\, 
 sensor configurations\, or external effects on the monitoring outcomes. 
 This parallel approach allows the interpretation of measured data in lig
 ht of physically plausible mechanisms identified in the simulations. The
  presented methodology supports a shift from conventional fixed-interval
  inspections toward predictive maintenance strategies\, with data-driven
  intervention planning based on objective structural condition assessmen
 ts. The combined use of SSDD for both empirical and simulation-based stu
 dies demonstrates high sensitivity to damage and provides valuable insig
 ht for the long-term stewardship of critical infrastructure.