BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//EURODYN//Schedule//DE
CALSCALE:GREGORIAN
METHOD:PUBLISH
BEGIN:VTIMEZONE
TZID:Europe/Berlin
X-LIC-LOCATION:Europe/Berlin
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:19700329T020000
RRULE:FREQ=YEARLY;BYMONTH=3;BYDAY=-1SU
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:19701025T030000
RRULE:FREQ=YEARLY;BYMONTH=10;BYDAY=-1SU
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
UID:477@eurodyn2026.org
DTSTAMP:20261026T144037Z
DTSTART;TZID=Europe/Berlin:20260929T163000
DTEND;TZID=Europe/Berlin:20260929T165000
SUMMARY:Structural Health Monitoring of the Ancient Sheikhantaur Mausoleu
 m in Tashkent (Uzbekistan) by Laser Scanning and Ambient Vibration Studi
 es
LOCATION:Room F303
DESCRIPTION:MS 11\n\nPresenter: Takhirov\, Shakhzod\n\nAuthors: Takhirov\
 , Shakhzod\; Yuvmitov\, Anvar\; Kosimov\, Elbek\; Аkhundjаnov\, Dilmurod
 \; Toshpulatov\, Salimjon\; Bozorkulov\, Sukhrob\; Sherniyozov\, Khasan\
 ; Nishonov\, Nematulla\; Shamansurov\, Ravshan\n\nChair: Mendes\, Nuno\n
 \nAbstract: Sheikhantaur is an ancient heritage complex\, with the cente
 rpiece being the Mausoleum of Sheikh Hovendi at-Tahur (Sheikhantaur). It
  was built in the 14th century and is one of the most important architec
 tural monuments in Tashkent\, Uzbekistan. It is a masonry structure with
  thick walls\, consisting of two halls connected by a small door. Each h
 all has its own globe. The globes are connected to form the structure's 
 roof. Two structural health monitoring studies were performed on the str
 ucture. First\, the structure was investigated using a terrestrial laser
  scanner to obtain a high-accuracy 3D digital twin. Both the interior an
 d exterior surfaces of the structure were laser-scanned. Second\, an amb
 ient vibration study of the monument was conducted using high-sensitivit
 y accelerometers. The resonant frequencies and vibration modes were obta
 ined from this investigation. In addition\, the level of vibrations caus
 ed by a construction nearby was studied. The paper presents the results 
 of these two studies.
URL:https://eurodyn2026.org/submission/477
END:VEVENT
END:VCALENDAR