BEGIN:VEVENT
UID:203@eurodyn2026.org
DTSTAMP:20261026T144037Z
DTSTART;TZID=Europe/Berlin:20260929T163000
DTEND;TZID=Europe/Berlin:20260929T165000
SUMMARY:Compensation of Environmental and Operational Variations in Wind 
 Turbine Natural Frequencies using SCADA data
LOCATION:Room F142
DESCRIPTION:MS 06\n\nPresenter: Pereira\, Sérgio\n\nAuthors: Rubino\, Ani
 ta Maria\; Pereira\, Sergio\; Civera\, Marco\; Magalhães\, Filipe\n\nCha
 ir: Höffer\, Rüdiger\n\nAbstract: Modal tracking is a fundamental tool t
 hat enables continuous dynamic Structural Health Monitoring (SHM). Yet\,
  trends in identified natural frequencies\, taken in isolation\, cannot 
 be uniquely attributed to structural changes – even less to occurring da
 mage. In fact\, modal parameters are influenced by environmental and ope
 rational variations (EOVs). These unde-sired influences are critical in 
 the monitoring of all types of Civil Engineering structures\, including 
 wind turbines\, where wind speed and direction govern operating state an
 d loading\, thereby altering the vibrational response. Here\, a data-dri
 ven approach is presented to tackle this problem. Using regression model
 s and Machine Learning (ML)-enhanced data analysis\, the proposed method
 ology minimizes external effects using Supervisory Control and Data Acqu
 isition (SCADA) measurements from a utility-scale onshore turbine. The p
 ortion of frequency variability attributable to am-bient and operating c
 onditions is thus predicted and then subtracted to yield residuals linke
 d primarily to mechanical condition. Control-chart analysis of the resid
 uals demonstrates sub-stantially reduced EOV sensitivity and improved re
 sponsiveness to incipient faults.  These results show that EOV-compensat
 ed modal tracking provides robust SHM indicators for wind turbines and i
 ncreases sensitivity to damage-related anomalies.