SUMMARY:Numerical analysis of foundation damping for monopiles
LOCATION:Room F142
DESCRIPTION:MS 06\n\nPresenter: Sanders\, Jan-Immo\n\nAuthors: Achmus\, M
 artin\; Sanders\, Immo\; Abdel-Rahman\, Khalid\; Saathoff\, Jann-Eike\n\
 nChair: Höffer\, Rüdiger\n\nAbstract: For offshore wind energy structure
 s\, fatigue loads\, which depend on the natural frequency and the dampin
 g of the structure\, are of crucial importance and often design-driving.
  One source of damping\, besides aerodynamic\, hydrodynamic and structur
 al damping\, is foundation damping. The knowledge about the magnitude of
  foundation damping and in particular its dependency on loading conditio
 ns is scarce. Often\, the global damping ratio is just increased by a ce
 rtain roughly estimated amount or foundation damping is even fully negle
 cted. In recent studies\, resultant foundation damping values were deriv
 ed from 1g model tests on monopiles in sand (Sanders et al.\, 2025) and 
 the distribution of damping along the embedded monopile length was inves
 tigated (Jindal et al.\, 2024). In this paper\, the foundation damping o
 f a monopile is investigated by means of a numerical model. The Hardenin
 g Soil Small (HSS) material law available in the used Plaxis3D programme
  is applied to account for the complex elastoplastic material behavior o
 f soil. By applying un- and reloading with varying mean loads and cyclic
  load amplitudes\, both resultant foundation damping and the distributio
 n of local foundation damping along the embedded monopile length was det
 ermined. The mentioned 1g model tests from literature served as validati
 on data for the numerical model. With the validated model\, a parametric
  study on magnitude and distribution of damping dependent on loading con
 ditions and soil conditions was conducted. The results confirm that foun
 dation damping is highly dependent on loading conditions. Finally\, reco
 mmendations on the consideration of foundation damping in practical desi
 gn are given.