BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//EURODYN//Schedule//DE
CALSCALE:GREGORIAN
METHOD:PUBLISH
BEGIN:VTIMEZONE
TZID:Europe/Berlin
X-LIC-LOCATION:Europe/Berlin
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:19700329T020000
RRULE:FREQ=YEARLY;BYMONTH=3;BYDAY=-1SU
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:19701025T030000
RRULE:FREQ=YEARLY;BYMONTH=10;BYDAY=-1SU
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
UID:308@eurodyn2026.org
DTSTAMP:20261026T144037Z
DTSTART;TZID=Europe/Berlin:20260929T152000
DTEND;TZID=Europe/Berlin:20260929T154000
SUMMARY:Integration of Stay Load Cell Measurements and Data Normalization
  for Structural Health Monitoring of Cable-Stayed Bridges
LOCATION:Room F102
DESCRIPTION:MS 14\n\nPresenter: Quarchioni\, Simone\n\nAuthors: Quarchion
 i\, Simone\; Tentella\, Luca\; Nicoletti\, Vanni\; Carbonari\, Sandro\; 
 Gara\, Fabrizio\n\nChair: Cunha\, Álvaro\n\nAbstract: This study present
 s an integrated and data driven monitoring framework for a cable-stayed 
 bridge that integrates traditional accelerometric measurements with load
  cell data to achieve a comprehensive structural assessment. Acceleromet
 ers\, load cells\, a weather station\, and ther-mocouples are integrated
  into the monitoring system to capture both structural and environ-menta
 l parameters affecting the dynamic behaviour of the bridge. The work inv
 estigates how different data normalization approaches and environmental 
 conditions affect the accuracy of damage detection. After a procedure of
  modal tracking\, advanced methods for data normaliza-tion are applied\,
  including neural network-based normalization procedures aimed at reduci
 ng the effects of temperature\, wind\, and traffic fluctuations. The nor
 malized outputs serve as inputs to Hotelling control charts that are ana
 lysed to assess the sensitivity\, stability\, and reliability of each no
 rmalization approach. A comparative study is also conducted between cont
 rol charts derived from load cell based modal frequencies and those obta
 ined from accelerometric data\, assessing their relative diagnostic capa
 bility under varying environmental conditions. Results show that the dif
 ferent normalization strategies significantly affect control chart robus
 tness and their ability to discern environmental effects from potential 
 structural anomalies. The proposed methodology presents a reliable basis
  for long term monitoring of cable-stayed bridges by us-ing a limited bu
 t efficient sensor network.
URL:https://eurodyn2026.org/submission/308
END:VEVENT
END:VCALENDAR