SUMMARY:Dynamic Behavior of the Colonial 17th Century Church La Merced in
  the Historic Center of Cusco\, Perú
LOCATION:Room F303
DESCRIPTION:MS 11\n\nPresenter: Rojas\, Julio\n\nAuthors: Bravo\, Jose\; 
 Mercerat\, Diego\; Montesinos\, Mijail\; Rojas-Bravo\, Julio\; Combey\, 
 Andy\n\nChair: Mendes\, Nuno\n\nAbstract: This research focuses on the d
 ynamic characterization of the Church of La Merced\, a colonial building
  located in the Historic Center of Cusco (Perú)\, supported by an integr
 ated 3D geometric survey. Built in the mid-17th century and composed of 
 stone and brick masonry\, the church features a 26-meter-high eccentric 
 bell tower\, covers an area of approximately 1\,470 m² and is part of a 
 larger architectural complex known as the Temple and Convent of La Merce
 d. Throughout its history\, this building suffered significant seismic d
 amage. It was rebuilt after the historical earthquake of 1650 (M ~7.1\; 
 IMM = VIII–IX). The subsequent earthquakes of 1950 (M ~ 6.0\; IMM = VII)
  and 1986 (Ms = 5.3\; IMM = VI) mainly affected the tower\, vaults\, dom
 es\, and principal walls of the reconstructed temple. The dynamic charac
 terization was conducted using an integrated experimental campaign combi
 ning velocimeters and accelerometers for the structural dynamic identifi
 cation\, and a velocimeter-based ambient noise recording for soil charac
 terization through HVSR analysis. For the bell tower\, fundamental frequ
 encies of approximately 3.1–3.2 Hz (transverse) and 3.7 Hz (longitudinal
 ) were identified. A global mode involving the nave walls was identified
  at approximately 2.7 Hz. A mode at approximately 6.9 Hz was also identi
 fied\, involving the nave walls\, the dome region\, and the bell tower\,
  where the dome exhibits predominantly longitudinal motion while the tow
 er zone responds in the transverse direction\, reflecting the influence 
 of the existing structural configuration on the coupled dynamic response
 . The soil fundamental frequency was estimated at 0.8 Hz from the HVSR a
 nalysis\, relatively far from the structural frequencies of the monument
 . The results from the Operational Modal Analysis revealed a frequency-d
 ependent coupling behavior among the main structural elements\, with dif
 ferent structural components exhibiting contrasting directional behavior
  depending on the frequency range considered. This study provides a reli
 able geometric and experimental basis for the calibration of a finite el
 ement model aimed at the ongoing structural assessment of the building u
 nder different seismic excitations.