DESCRIPTION:MS 06\n\nPresenter: Civera\, Marco\n\nAuthors: Taiariol\, Luc
 a\; Civera\, Marco\; Pereira\, Sérgio\; Magalhães\, Filipe\n\nChair: Höf
 fer\, Rüdiger\n\nAbstract: Operational Modal Analysis (OMA) is an increa
 singly popular tool for tracking the dynamic properties of wind turbines
  (WTs) under normal operational conditions (NOCs). However\, most automa
 ted deployments still focus on accelerometers. This short paper reports 
 some preliminary considerations for a thorough investigation into altern
 ative sensing devices. In particular\, it is experimentally studied how 
 tower-base strain gauges can support system identification\, also when r
 ecast as sectional bending moments rather than directly as local strain 
 channels. The discussion reported here is based on a real-life field cas
 e study: long-term measurements from an onshore\, full-scale WT tower. T
 en-minute datasets are pro-cessed through an end-to-end Automated OMA (A
 OMA) pipeline\, comprising covariance-driven Stochastic Subspace Identif
 ication (SSI-COV)\, stabilisation diagram cleaning\, densi-ty-based clus
 tering (DBSCAN)\, reference extraction\, and modal tracking. This work d
 emon-strates that direct strain channels retain clear low-frequency info
 rmation and reveal the first global bending pair at the single-dataset l
 evel\, but they do not provide sufficiently ho-mogeneous clusters for fu
 lly unsupervised reference extraction over extended periods. In contrast
 \, bending moments reconstructed from opposite gauges improve the observ
 ability of global flexural behaviour. In the proposed bending-moment-bas
 ed AOMA\, the resulting reference frequencies for the first fore-aft (FA
 ) and side-side (SS) modes remain within a 0.2% of the respective accele
 ration-based benchmarks. Hence\, the results support the use of bending 
 moments as a suitable strain-derived output for the modal tracking of th
 e first tower bending pair. They do not replace multi-level acceleromete
 rs for richer multi-mode characterisation\, but they offer a practical a
 lternative for tower-level structural health monitoring (SHM)\, if strai
 n gauges are already installed.