SUMMARY:Long-term Remote Vibration Monitoring for Scour Detection of a Ma
 sonry Arch Bridge
LOCATION:Room F102
DESCRIPTION:MS 14\n\nPresenter: Hanabata\, Yukito\n\nAuthors: Hanabata\, 
 Yukito\n\nChair: Cunha\, Álvaro\n\nAbstract: Frequent heavy rainfall eve
 nts caused by global warming are increasing the scour risk of bridges\, 
 including historical masonry bridges. Structural Health Monitoring (SHM)
  technologies have been widely adopted for detecting bridge scour. Among
  these\, monitoring the changes in the rocking-mode frequency of bridge 
 piers has shown promise. However\, vibration-based scour detection for m
 asonry arch bridges has not been fully explored. One major challenge lie
 s in the difficulty of monitoring the rocking mode of masonry arch bridg
 es due to weak vibration signals and high ambient noise. Despite these c
 hallenges\, recent advances in sensor technology enable precise measurem
 ent of weak vibrations\, while stochastic operational modal analysis met
 hods\, such as the Fast Bayesian FFT approach\, can address uncertainty 
 in a probabilistic framework. This study presents a long-term vibration-
 based scour monitoring of an in-service historical masonry arch bridge i
 n Northern Ireland\, UK. High-precision tri-axial accelerometers were in
 stalled on the upstream spandrel wall piers to capture vibration respons
 es especially the rocking mode. The bridge’s natural frequencies were id
 entified using the Fast Bayesian FFT method\, and their daily variations
  were analysed. Differences in frequency characteristics between daytime
  and nighttime were observed\, and correlations between the identified f
 requencies and water levels were examined to enhance the reliability of 
 natural frequency as an index for scour assessment.