BEGIN:VEVENT
UID:162@eurodyn2026.org
DTSTAMP:20261026T144037Z
DTSTART;TZID=Europe/Berlin:20260929T142000
DTEND;TZID=Europe/Berlin:20260929T144000
SUMMARY:Vibration-based assessment and model calibration of a heritage ma
 sonry church after post-earthquake strengthening
LOCATION:Room F303
DESCRIPTION:MS 11\n\nPresenter: Masciotta\, Maria Giovanna\n\nAuthors: Ma
 sciotta\, Maria Giovanna\; Pellegrini\, Daniele\; Barontini\, Alberto\; 
 Potenza\, Francesco\; Pepe\, Massimiliano\; Brando\, Giuseppe\; Spacone\
 , Enrico\n\nChair: Mendes\, Nuno\n\nAbstract: The preservation of histor
 ical masonry structures in seismic-prone regions increasingly re-lies on
  vibration-based techniques for assessing structural integrity and suppo
 rting model-driven vulnerability analyses. Within this framework\, the p
 resent study investigates the dynamic behaviour of the Church of SS. Tri
 nità in Popoli Terme (Italy)\, a significant heritage building that sust
 ained severe damage during the 2009 L’Aquila earthquake and was subseque
 ntly repaired and strengthened. The work has been developed in the conte
 xt of the GENESIS project – Seismic risk management for touristic valori
 sation of the historical centres of Southern Italy\, aimed at integratin
 g seismic risk management with the enhancement of cultural heritage. An 
 extensive ambient vibration test campaign was performed to characterize 
 the dynamic properties of the structure through Operational Modal Analys
 is (OMA). The identified modal parameters - natural frequencies and mode
  shapes - were used to calibrate a detailed finite element model of the 
 church developed in the NOSA-ITACA code\, which implements the constitut
 ive equation of no-tension materials for simulating the mechanical respo
 nse of historic masonry structures. The model updating process proved pa
 rticularly challenging due to the structural complexity of the building 
 as well as to uncertainties in boundary and soil conditions. Nonetheless
 \, it led to a consistent representation of the current structural state
  after the post-earthquake strengthening works. The updated model provid
 es a robust basis for subsequent seismic vulnerability assessments and d
 emonstrates the effectiveness of OMA-based model updating in improving t
 he reliability of numerical simulations of complex non-conventional heri
 tage structures.
URL:https://eurodyn2026.org/submission/162