SUMMARY:Transfer Learning of Multi-Fidelity Models for Damage Identificat
 ion: A Case Study of Laboratory Steel Frames
LOCATION:Room F102
DESCRIPTION:MS 14\n\nPresenter: López-Cuervo\, Antonio\n\nAuthors: Tamuly
 \, Pranjal\; López-Cuervo\, Antonio\; Tomassini\, Elisa\; Ubertini\, Fil
 ippo\; Chiachío\, Juan\; García-Macías\, Enrique\n\nChair: Lombaert\, Ge
 ert \n\nAbstract: Vibration-based monitoring through Operational Modal A
 nalysis (OMA) is one of the most widely adopted approaches in Structural
  Health Monitoring (SHM)\, as it allows the extraction of modal paramete
 rs from ambient vibrations in a non-intrusive and cost-effective way. Wh
 en a finite element (FE) model is available\, these identified modal dat
 a can also be used to update it\, enabling variations in model parameter
 s to be related to damage. However\, model-based schemes generally requi
 re a high-fidelity (HF) numerical model\, which is often unavailable in 
 practice because design or assessment models include simplifications\, s
 uch as idealized boundary conditions\, rigid joints\, or lumped masses\,
  that limit their predictive capability. To address this limitation\, th
 is work proposes a two-stage multi-fidelity transfer learning framework 
 for zero-shot structural damage detection. A dual-encoder neural network
  is first pre-trained on HF simulations from a source structure and then
  fine-tuned on calibrated low-fidelity (LF) simulations of the target st
 ructure using differential learning rates. The framework performs floor-
 level damage localisation and enables damage classification from frequen
 cy drop signatures without requiring experimental training data. Validat
 ion on experimental measurements from two damage scenarios on a five-sto
 rey steel frame benchmark shows 99.3% zero-shot floor localisation accur
 acy. Moreover\, t-SNE visualisation of the frequency encoder’s learned e
 mbeddings reveals distinct clusters for the two experimental damage clas
 ses\, despite the absence of damage class labels during training.
URL:https://eurodyn2026.org/submission/271