BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//EURODYN//Schedule//DE
CALSCALE:GREGORIAN
METHOD:PUBLISH
BEGIN:VTIMEZONE
TZID:Europe/Berlin
X-LIC-LOCATION:Europe/Berlin
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:19700329T020000
RRULE:FREQ=YEARLY;BYMONTH=3;BYDAY=-1SU
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:19701025T030000
RRULE:FREQ=YEARLY;BYMONTH=10;BYDAY=-1SU
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
UID:610@eurodyn2026.org
DTSTAMP:20261026T144037Z
DTSTART;TZID=Europe/Berlin:20260929T123000
DTEND;TZID=Europe/Berlin:20260929T125000
SUMMARY:Inerter-based seismic control of cable-stayed bridges under trans
 verse excitation
LOCATION:Room F303
DESCRIPTION:MS 23\n\nPresenter: Santoro\, Roberta\n\nAuthors: Mazzeo\, Ma
 tteo\; Santoro\, Roberta\; Sciutteri\, Silvia\; Ricciardi\, Giuseppe\n\n
 Chair: Di Matteo\, Alberto\n\nAbstract: Cable-stayed bridges provide an 
 efficient infrastructural solution due to their ability to span long dis
 tances and their structural slenderness. Nevertheless\, in the common fl
 oating-deck arrangement\, these systems may experience significant damag
 e under strong seismic excitations\, caused by excessive transverse disp
 lacements and potential impacts between the deck and the towers.  In the
  transverse direction\, seismic protection is commonly achieved by linki
 ng the tower and the deck using passive control devices including viscou
 s or metallic dampers. Studies have further shown that coupling a dissip
 ator with a negative stiffness element enhances motion and energy dissip
 ation\, suggesting the potential benefits of hybrid devices combining da
 mpers and inerters. The present study investigates the transverse vibrat
 ion control of cable-stayed bridges under seismic loading using a novel 
 Inerter-Based Dissipator (IBD) configuration. A simplified dynamic model
  is proposed to capture the bridge’s transverse response\, while the opt
 imal device parameters are obtained by representing ground motion as a f
 iltered Gaussian stochastic process and accounting for damper nonlineari
 ties via the Stochastic Linearization Technique. The effectiveness of th
 e proposed configuration in reducing the transverse relative displacemen
 t between the deck and the tower is assessed on a fan-type cable-stayed 
 bridge\, demonstrating its superior performance compared to the conventi
 onal solution employing viscous dampers.
URL:https://eurodyn2026.org/submission/610
END:VEVENT
END:VCALENDAR