BEGIN:VEVENT
UID:638@eurodyn2026.org
DTSTAMP:20261026T144037Z
DTSTART;TZID=Europe/Berlin:20260929T115000
DTEND;TZID=Europe/Berlin:20260929T121000
SUMMARY:Performance and robustness of a new passive damper: Component tes
 ting\, characterization\, and pseudo dynamic testing
LOCATION:Room F303
DESCRIPTION:MS 23\n\nPresenter: Kalfas\, Konstantinos N.\n\nAuthors: Kalf
 as\, Konstantinos N.\; Makris\, Nicos\n\nChair: Di Matteo\, Alberto\n\nA
 bstract: n the past 20 years\, there have been witnessed appreciable sei
 smic damage and several weak-story failures of mid-rise and high-rise bu
 ildings that have been documented after major earthquakes in urban envir
 onments\; as well as recent failures of the fluid dampers end seals that
  resulted in detrimental leaking and an estimated retrofit cost of milli
 ons (the San Francisco-Oakland Bay Bridge located at the San Francisco B
 ay is an indicative example). In view of these devastating consequences\
 , this research is partly motivated by the need to develop sustainable e
 nergy dissipation devices that do not suffer from oil leakage due to fai
 lure of their end seals and from the occasional displacement limitations
  of yielding steel dampers\; and partly from the need to develop a robus
 t damper that consists only of traditional civil engineering materials (
 sand and steel) in association with the use of post -tensioned steel rod
 s with which practitioner civil engineers are familiar. Past failures of
  fluid dampers are both disruptive and costly\, therefore not in-line wi
 th the current design paradigm of sustainable engineering\, where the de
 sign and construction of structural systems shall meet acceptable perfor
 mance levels at present and in the years to come without compromising th
 e ability of future generations to use\, maintain\, and benefit from the
 m. This study presents results from an extensive experimental campaign w
 ith a pressurized sand damper (PSD) which does not suffer from the chall
 enges of viscous heating\, the failure of its end seals and the long str
 oke limitations\, and addresses the quest for velocity-independent (hyst
 eretic) dissipation. The experimental campaign includes physical testing
 \, real-time hybrid simulation (RTHS) testing and the development of the
  analytical model that captures the behavior of the PSD. The robustness 
 of the PSD is also assessed by subjecting it to extreme temperatures and
  humidity.
URL:https://eurodyn2026.org/submission/638
END:VEVENT