BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//EURODYN//Schedule//DE
CALSCALE:GREGORIAN
METHOD:PUBLISH
BEGIN:VTIMEZONE
TZID:Europe/Berlin
X-LIC-LOCATION:Europe/Berlin
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:19700329T020000
RRULE:FREQ=YEARLY;BYMONTH=3;BYDAY=-1SU
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:19701025T030000
RRULE:FREQ=YEARLY;BYMONTH=10;BYDAY=-1SU
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
UID:285@eurodyn2026.org
DTSTAMP:20261026T144037Z
DTSTART;TZID=Europe/Berlin:20260929T115000
DTEND;TZID=Europe/Berlin:20260929T121000
SUMMARY:Refinement of the Correlation Length Method for Predicting Vortex
 -Induced Vibrations in Slender Structures
LOCATION:Room A310
DESCRIPTION:MS 19\n\nPresenter: Fontecha Gonzalez\, Robert\n\nAuthors: Ba
 ltes\, Mathias\; Kemper\, Frank\; Fontecha\, Robert\n\nChair: Denoël\, V
 incent\n\nAbstract: Vortex-induced vibrations (VIV) are a major design c
 oncern for slender towers\, chimneys\, and wind-turbine structures. The 
 effective correlation-length method\, adopted in current design standard
 s such as Eurocode 1\, remains widely used but has not been comprehensiv
 ely validated across the full parameter space relevant to modern lightwe
 ight structures. This study presents new experimental results obtained i
 n the boundary-layer wind tunnel of RWTH Aachen using the forced-oscilla
 tion method. The experiments quantify the influence of structural slende
 rness\, oscillation amplitude\, and atmospheric boundary-layer turbulenc
 e on the correlation length governing cross-wind response. Two rigid alu
 minium models with different slenderness ratios were tested under smooth
  and turbulent flow conditions representative of terrain categories I–IV
 .  To complement these measurements and validate the aerodynamic excitat
 ion obtained from the forced-vibration approach\, additional aeroelastic
  tests were conducted using lightweight carbon-fibre tube models capable
  of reproducing self-excited vibration behaviour under resonance. The co
 mbined results confirm the consistency of both testing approaches and pr
 ovide insight into the dynamic coupling between flow and structure.  Mea
 sured correlation lengths generally exceed current standard values\, par
 ticularly under turbulent flow and higher oscillation amplitudes\, indic
 ating that existing design provisions may underestimate aerodynamic exci
 tation. The findings support a refined formulation of the correlation-le
 ngth-based VIV model\, improving its applicability to modern tall and fl
 exible structures and enabling more reliable fatigue and serviceability 
 assessments.
URL:https://eurodyn2026.org/submission/285
END:VEVENT
END:VCALENDAR