SUMMARY:Damping identification under non-ideal conditions: Performance as
 sessment of the random decrement technique ranked by peak amplitude
LOCATION:Room A310
DESCRIPTION:MS 19\n\nPresenter: Kirsch\, Julie\n\nAuthors: Kirsch\, Julie
 \; Cabboi\, Alessandro\; Bronkhorst\, Alexander Johannes\; van Dijk\, Th
 omas\; Lourens\, Eliz-Mari\; Sanchez Gomez\, Sergio\n\nChair: Denoël\, V
 incent\n\nAbstract: Damping identified from response measurements of hig
 h-rise buildings often exhibits significant scatter\, posing a challenge
  for reliable interpretation and practical use. The Random Decrement Tec
 hnique (RDT) stands out for its robustness and its ability to identify a
 mplitude-dependent damping by adjusting the triggering condition.    Thi
 s study investigates the performance of the RDT ranked by peak amplitude
  (Peak RDT) under conditions deviating from the method’s mathematical as
 sumptions. The analysis considers constant and amplitude-dependent dampi
 ng models as well as stationary and non-stationary excitation conditions
 . The identified damping values are assessed against a known input. Nume
 rical studies employing a Monte Carlo approach are conducted to generate
  distributions of the damping ratio\, from which accuracy and precision 
 are evaluated.  Under stationary loading conditions\, the mean damping i
 s accurate for the linear system across all relative amplitudes. For the
  non-linear system\, the accuracy of mean damping strongly depends on th
 e length of the segments considered. Sampling long segments results in a
 n overly linearized damping function. For both systems\, the precision o
 f damping estimates is significantly reduced at low and high relative am
 plitudes due to poor approximations of the system’s free decay at these 
 amplitudes.  Three types of non-stationarity excitations are considered:
  time-varying mean\, time-varying variance\, and their combination. Due 
 to the underlying assumptions of the Peak RDT\, damping values derived f
 rom response data exhibiting a time-varying mean result in significant a
 ccuracy errors in both linear and non-linear systems. In contrast\, the 
 method demonstrates robustness when applied to response data with time-v
 arying variance.