SUMMARY:Frequency-Based Cable Force Identification Correction Considering
  an Attached Concentrated Mass under Permanent Active Excitation
LOCATION:Room F102
DESCRIPTION:MS 14\n\nPresenter: Gao\, Zelei\n\nAuthors: Gao\, Zelei\; Che
 n\, Shufan\; Ye\, Peng\n\nChair: Cunha\, Álvaro\n\nAbstract: For long-te
 rm cable force monitoring in situations with insufficient ambient excita
 tion\, a permanently installed active-excitation system combined with th
 e frequency-based method provides a feasible technical solution. However
 \, the attached mass of the excitation unit may introduce non-negligible
  bias into conventional frequency-based cable force identification. To a
 ddress this issue\, an analytical vibration model of a tensioned cable w
 ith a single attached concentrated mass is established in this study. Th
 e exact characteristic equation\, incorporating both the mass ratio and 
 the attachment location\, is derived\, and the corresponding exact frequ
 ency-cable force relationship is obtained. In addition\, an explicit app
 roximate correction formula is developed for the small-mass-ratio case. 
 To validate the proposed formulations\, a pretensioned cable numerical m
 odel is established in LMGC90. The fundamental frequency is identified f
 rom impact-induced free-decay responses\, and parametric studies are car
 ried out to compare the conventional method\, the exact correction\, and
  the approximate correction. The results show that the attached concentr
 ated mass causes a significant systematic underestimation when the conve
 ntional frequency-based method is directly applied. The error increases 
 with the mass ratio and shows a clear dependence on the attachment locat
 ion. The exact correction based on the rigorous characteristic equation 
 can effectively eliminate the bias. The approximate correction is explic
 it and computationally efficient\, and it provides satisfactory accuracy
  for small to moderate mass ratios. When the mass ratio becomes relative
 ly large or the attachment is located in a sensitive region\, the exact 
 correction should be adopted. The proposed correction framework provide 
 a practical basis for parameter selection\, sensor/exciter installation 
 design\, and online cable force identification in permanently installed 
 active-excitation monitoring systems.