BEGIN:VEVENT
UID:365@eurodyn2026.org
DTSTAMP:20261026T144037Z
DTSTART;TZID=Europe/Berlin:20260928T163000
DTEND;TZID=Europe/Berlin:20260928T165000
SUMMARY:Shake-Table Tests of a Three-Storey Steel Structure with Resilien
 t Slip-Friction Joints (RSFJ)
LOCATION:Room F303
DESCRIPTION:MS 23\n\nPresenter: Chan\, Nicholas\n\nAuthors: Chan\, Nichol
 as\; Hashemi\, Ashkan\; Assadi\, Soheil\; Bagheri\, Hamed\; Clifton\, Ch
 arles\; MacRae\, Gregory\; Dhakal\, Rajesh\; Jia\, Liang-Jiu\; Quennevil
 le\, Pierre\n\nChair: Di Matteo\, Alberto\n\nAbstract: Several innovativ
 e structural systems utilizing friction dampers were tested during the R
 OBUST shake-table program. This paper presents 3 configurations of the R
 esilient Slip-Friction Joint (RSFJ) in a full-scale steel structure: as 
 part of tension-only braces (TOB)\, tension-compression braces (TCB)\, a
 nd moment-resisting frame (MRF) joints along the structure’s length (x-d
 irection). Symmetric friction connections (SFC) were used along the widt
 h (y-direction). Each configuration was subjected to the 1940 El Centro 
 ground motion scaled to increasing intensities\, ultimately reaching a p
 eak ground acceleration (PGA) of 0.5g (=1.2 × design intensity). Peak di
 splacements at the top floor were 0.66%\, 0.98% and 1.26% of the total h
 eight for TOB\, TCB and MRF systems respectively. The corresponding inte
 r-storey drifts were 0.87%\, 1.11% and 1.62%. RSFJ systems were essentia
 lly self-centering\, with residual drifts limited to 0.03%. Peak floor a
 ccelerations were 0.67g (TOB)\, 0.66g (TCB) and 0.62g (MRF) in unidirect
 ional tests. Acceleration spikes manifested in different ways\, includin
 g direction reversal at peak deflection (Mode 1)\, sharp deceleration wh
 en joints close at the zero/upright position (Mode 1)\, and resonance un
 der higher Mode 2 excitations. In bidirectional tests\, slight torsion d
 ue to unbalanced SFC deformations (y-direction) and uneven loading of RS
 FJs (x-direction) exacerbated the deceleration\, contributing to the lar
 gest accelerometer reading of 0.95g (TCB). However\, peak displacements 
 were relatively unaffected\; similar responses as unidirectional tests i
 ndicate effective performance during simultaneous out-of-plane shaking. 
 Stable RSFJ performance and absence of damage over multiple\, design-lev
 el earthquakes\, support their viability in low-to-medium rise structure
 s for expediting post-earthquake functional recovery and increased resil
 ience against earthquakes.
URL:https://eurodyn2026.org/submission/365
END:VEVENT
END:VCALENDAR