BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//EURODYN//Schedule//DE
CALSCALE:GREGORIAN
METHOD:PUBLISH
BEGIN:VTIMEZONE
TZID:Europe/Berlin
X-LIC-LOCATION:Europe/Berlin
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:19700329T020000
RRULE:FREQ=YEARLY;BYMONTH=3;BYDAY=-1SU
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:19701025T030000
RRULE:FREQ=YEARLY;BYMONTH=10;BYDAY=-1SU
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
UID:103@eurodyn2026.org
DTSTAMP:20261026T144037Z
DTSTART;TZID=Europe/Berlin:20260928T152000
DTEND;TZID=Europe/Berlin:20260928T154000
SUMMARY:Dynamic response of cable-stayed bridges with seismic isolation s
 ystem and eddy current dampers.
LOCATION:Room F107
DESCRIPTION:MS 24\n\nPresenter: Fajardo Contreras\, Santiago\n\nAuthors: 
 Fajardo Contreras\, Santiago\; Ramírez Vargas\, Abner\; Ortiz Cano\, Nel
 son\n\nChair: Kashani\, Mohammad Mehdi\n\nAbstract: A cable-stayed bridg
 e is a structural system consisting of a deck supported by cables anchor
 ed to a tower. This type of system is very flexible\, allows large spans
  ranging from 150 to 600 meters\, which tower and deck connections may s
 uffer damage in conditions of strong winds and earthquakes. This study e
 valuates the performance of a seismic isolation system with eddy current
  dampers (ECD) applied in a cable-stayed bridge. ECD have been recently 
 implemented in suspension bridges. Their main advantage is the lower mai
 ntenance and probability of long service life\, even so the magnitude of
  the force developed is still the focus of attention of researchers. Thi
 s study examines the acceleration and displacement response of a cable-s
 tayed bridge with seismic isolators and ECD dampers. The structural syst
 em studied corresponds to a cable-stayed bridge located in Illinois-Unit
 ed States. In the proposal were obtained the dynamic response of three s
 eismic protection systems\, conventional\, seismic isolators and isolati
 on systems with ECD. The model is developed in two-dimensional using the
  finite element method through MIDAS CIVIL. A parametric analysis of the
  seismic protection allowed to identify the effects on the reduction of 
 the dynamic response of the bridge. Finally\, some conclusions on the te
 chnical feasibility of these systems are listed.
URL:https://eurodyn2026.org/submission/103