SUMMARY:Stochastic analysis of footbridge vibrations using an analytical 
 moving pedestrian model
LOCATION:Room B302
DESCRIPTION:MS 07\n\nPresenter: Most\, Thomas\n\nAuthors: Most\, Thomas\;
  Häselbarth\, Heiner\; Bock\, Sebastian\n\nChair: Van den Broeck\, Peter
  \n\nAbstract: In the design of footbridges\, the pedestrian load is oft
 en simplified by a fixed single load in the middle-span of the bridge. W
 ith this assumption\, the bridge can be simplified to a single-degree-of
 -freedom-system (SDOF) and analyzed very efficiently with simple equatio
 ns. If a moving load is considered\, usually a more complex finite eleme
 nt model is necessary and the analysis requires generally a much more de
 manding numerical time integration.  Within this paper\, we will present
  an analytical model for a moving pedestrian load along a simplified foo
 tbridge with given cross-section properties. The load model assumes a co
 nstant pedestrian stream across the bridge and is represented as a perio
 dic load within the time domain. With help of Fourier series\, we will t
 ransfer this load-time-history into the frequency domain.  The simplific
 ation of the original dynamical system to a series of SDOF system is pos
 sible and the solution for the periodic load can be achieved by analytic
 al formulas.   Based on this analytical model\, we will analyze a footbr
 idge under a pedestrian stream with random load amplitudes and varying p
 hase angles. As reference\, we will compare the solution with a finite e
 lement model with full time integration. The results are compared to rec
 ommended formulas in typical footbridge design guidelines.