SUMMARY:Temperature effects on Digital Twins: Finite Element Model Updati
 ng of a Scaled Jacket Foundation
LOCATION:Room F128
DESCRIPTION:MS 22\n\nPresenter: Høgsberg\, Jan\n\nAuthors: Steffensen\, M
 ikkel\; Leble\, Vladimir\; Augustyn\, Dawid\; Høgsberg\, Jan\n\nChair: H
 øgsberg\, Jan\n\nAbstract: Various interpretations of the digital twin c
 oncept exist in practice and the scientific communities\, with most of t
 hem sharing a common foundation: a base finite element (FE) model and a 
 model updating procedure that uses data from the concerned real-world or
  physical structure. Commonly\, the applied model updating method aims t
 o align the dynamic properties\, such as natural frequencies\, modal dam
 ping ratios\, or mode shape values\, with those from the actual structur
 e\, using underlying numerical minimization schemes. The present study i
 nvestigates the ability of a digital twin to capture the influence of en
 vironmental changes on a jacket-type offshore wind turbine foundation. F
 or a real-world offshore structure\, a few important operational conditi
 ons may be the variations in temperature\, wave height\, wind speed\, or
  rotor state. In particular\, it remains unclear how changes in the moda
 l parameters of a jacket foundation due to temperature changes affect th
 e model-updating parameters of the corresponding FE model. In this study
 \, we examine how model-updating parameters vary with temperature. An ex
 cessive amount of data is collected through experimental modal analysis 
 in an indoor laboratory environment with naturally varying temperatures.
  The data are then divided into a number of experiments\, for which the 
 modal parameters are obtained. Each set of modal parameters is then used
  to update the FE model. The results comprise distributions of the model
 -updating parameters as a function of temperature\, demonstrating the in
 fluence of temperature changes on a jacket-type foundation\, the uncerta
 inty in the model-updating parameters\, and the digital twin's ability t
 o capture the associated changes in the governing dynamic parameters.