BEGIN:VEVENT
UID:276@eurodyn2026.org
DTSTAMP:20261026T144037Z
DTSTART;TZID=Europe/Berlin:20260928T144000
DTEND;TZID=Europe/Berlin:20260928T150000
SUMMARY:Exploring structural dynamics in exceptionally low ambient noise:
  modal identification of a deep-underground steel frame
LOCATION:Room F303
DESCRIPTION:MS 23\n\nPresenter: Sepe\, Vincenzo\n\nAuthors: D'Agostino\, 
 Valentina\; Santilli Di Luia\, Gregory\; Masciotta\, Maria Giovanna\; Po
 tenza\, Francesco\; Sepe\, Vincenzo\; Vasta\, Marcello\n\nChair: Di Matt
 eo\, Alberto\n\nAbstract: Operational Modal Analysis (OMA) is a well-est
 ablished procedure used to identify the main modal parameters of a struc
 ture —natural frequencies\, mode shapes\, and damping ratios— by process
 ing experimental data acquired under operational conditions\, typically 
 from acceleration measurements at low vibration amplitudes. This type of
  experimental activity is also referred to ambient vibration testing (AV
 T)\, since civil structures are generally excited by broadband environme
 ntal inputs such as wind or low-amplitude ground motion. Numerous method
 ologies have been developed to identify dynamic properties from such mea
 surements\, generally assuming an unknown excitation source\; these are 
 commonly referred to as output-only methods. Consequently\, when designi
 ng these types of tests\, it is essential to ensure a low noise-to-signa
 l ratio. The present research investigates the feasibility and effective
 ness of AVT in environments characterized by exceptionally low ambient n
 oise\, such as the Gran Sasso National Laboratory (INFN-LNGS). The labor
 atory\, located within underground galleries approximately 1\,400 meters
  beneath the rock\, hosts experimental control rooms composed of three-s
 tory bolted steel frames. To properly design the type and placement of s
 ensors for a vibrational monitoring system\, ambient vibration tests wer
 e performed under different experimental configurations. Subsequently\, 
 the main modal parameters were identified by comparing results obtained 
 through various approaches. Finally\, based on the experimental outcome\
 , a sensitivity-based method was applied to update the numerical model f
 or prediction analyses. This work represents a preliminary step toward t
 he development of a Digital Twin dedicated to the laboratory’s facilitie
 s\, enabling enhanced structural assessment and continuous performance m
 onitoring in deep-underground environments.
URL:https://eurodyn2026.org/submission/276
END:VEVENT