SUMMARY:A probabilistic approach for the performance assessment of protec
 tive measures for masonry walls subjected to dynamic loading
LOCATION:Room F142
DESCRIPTION:MS 02\n\nPresenter: Stocchi\, Alessandro\n\nAuthors: Stocchi\
 , Alessandro\; Rosin\, Julia\n\nChair: Mitseas\, Ioannis\n\nAbstract: Pr
 essure-impulse (PI) diagrams are commonly employed in the design of prot
 ective structures subjected to blast loading. Several methods are availa
 ble for the definition of the iso-damage curves. Typically\, single-degr
 ee-of-freedom (SDOF) analytical models validated through experimental te
 sting on structural components are adopted. However\, with the availabil
 ity of adequate computational resources\, more refined and complex finit
 e element (FE)analyses can be performed enabling the consideration of a 
 broader range of physical phenomena and damage mechanisms. This is parti
 cularly relevant for masonry structures\, which are complex composite ma
 terial systems characterized by highly variable mechanical properties an
 d widespread use in construction worldwide (e.g.\, infill walls\, load-b
 earing structures\, vernacular architecture). In the presented research\
 , a method for the develop-ment of shock fragility curves for masonry wa
 lls with a probabilistic approach is presented. A FE model of masonry wa
 lls is developed in LS-Dyna and validated against experimental results f
 rom shock tube test of scaled masonry specimens. A Monte Carlo analysis 
 is then carried out by introducing uncertainties in the material models 
 (for both mortar and clay bricks)\, in the geometry\, and in the threat 
 scenario. Another probabilistic FE model is established\, incorporating 
 a polyurea protective layer applied to the inside surface of the wall. S
 hock fragility PI curves are generated for both unprotected and protecte
 d configurations to assess the performance of the protective measure. Th
 e presented method established a basis for the performance assessment of
  protective measures and enables the generation of generalized results s
 uitable for design applications\, ultimately supporting informed decisio
 n-making processes among stakeholders.