UID:245@eurodyn2026.org
DTSTAMP:20261026T144037Z
DTSTART;TZID=Europe/Berlin:20260928T144000
DTEND;TZID=Europe/Berlin:20260928T150000
SUMMARY:Comparative Performance of Micropile and Conventional Pile Retrof
 its: Strain-Dependent Head Stiffness from 1g Tests and Numerical Analysi
 s
LOCATION:Room A310
DESCRIPTION:MS 04\n\nPresenter: Goit\, Chandra Shekhar\n\nAuthors: Goit\,
  Chandra Shekhar\n\nChair: Müller\, Gerhard\n\nAbstract: Seismic retrofi
 tting of bridge foundations in urban environments must satisfy stringent
  performance requirements while contending with spatial constraints that
  preclude adding large-diameter piles. Micropiles offer a compact altern
 ative\, yet their soil-structure interaction (SSI) behaviour relative to
  conventional pile-addition remains insufficiently quantified across str
 ain levels.  This study combines nonlinear numerical modelling with scal
 ed 1g model testing to compare conventional pile-addition retrofits agai
 nst micropile retrofits. A baseline un-retrofitted 2×2 floating pile gro
 up\, a conventional pile-addition scheme\, and micropile retrofit config
 urations were evaluated to obtain head-level lateral stiffness under con
 trolled cyclic displacements\, with explicit treatment of soil nonlinear
 ity and soil-pile interface effects. Physical 1g model tests measured he
 ad-level impedance functions (IFs) for a 2×2 pile group retrofitted with
  micropiles at 0°\, 5°\, and 10° inclinations\; loading amplitudes were 
 varied to consider progressive nonlinearity in the surrounding soil.  At
  low strains\, micropiles (particularly when inclined) produce higher he
 ad-level stiffness than the un-retrofitted baseline. At higher strains\,
  nonlinearity in the surrounding soil reduces this stiffness advantage\,
  with micropile performance approaching or falling below that of the un-
 retrofitted baseline. The conventional retrofit\, on the other hand\, sh
 ows better performance than micropiles at such high strain levels. The c
 onvergent trends between physical model tests and numerical predictions 
 provide validated direction in selecting retrofit configurations based o
 n expected loading intensities in space-constrained sites\, clarifying t
 he strain-level regimes where micropiles offer optimal seismic performan
 ce.