BEGIN:VEVENT
UID:633@eurodyn2026.org
DTSTAMP:20261026T144037Z
DTSTART;TZID=Europe/Berlin:20260928T142000
DTEND;TZID=Europe/Berlin:20260928T144000
SUMMARY:Mitigation of Vortex-induced Vibration of a Long-span Bridge usin
 g Flexible Membranes
LOCATION:Room F128
DESCRIPTION:MS 20\n\nPresenter: Wang\, Chaoqun\n\nAuthors: Wang\, Chaoqun
 \; Xu\, Haoyu\; Huang\, Zhiwen\; Hua\, Xugang\; Chen\, Zhengqing\n\nChai
 r: Borri\, Claudio\n\nAbstract: In recent years\, several in-service lon
 g-span bridges have experienced unexpected vortex-induced vibration (VIV
 ). For example\, in 2020\, the Humen Bridge was closed for nearly 10 day
 s due to large-amplitude VIV\, causing significant economic losses and n
 egative social impacts. Once a bridge experiences VIV\, rapid vibration 
 mitigation thereby minimizing economic losses and negative social impact
 s are crucial. Therefore\, there is an urgent need to develop a rapid an
 d economically feasible mitigation measure that allows for modular desig
 n and quick assembly. Flexible membranes (FM) have been proved to be eff
 ective in suppressing VIV of bluff bodies\, however\, the effect and des
 ign of FMs for VIV mitigation of bridges have not been fully studied. In
  this study\, the unexpected VIV recently observed in a cable-stayed bri
 dge is described\, and a comprehensive experimental study of VIV mitigat
 ion using FMs is presented. A series of wind tunnel tests are carried ou
 t on a sectional model of the bridge girder\, to study the effect of ins
 tallation location\, arrangement\, geometric size\, material of FMs on t
 heir VIV-mitigation performance. After a series of aerodynamic optimizat
 ion\, segmented FMs installed under the wind fairings of the girder at i
 ntervals can successfully mitigate the large-amplitude VIV of the Π-shap
 ed girder. Above all\, FMs can be used as a temporary vibration mitigati
 on measure in emergency treatment of VIV of a long-span bridge\, buying 
 valuable transition time for the implementation of subsequent permanent 
 vibration mitigation measures.
URL:https://eurodyn2026.org/submission/633
END:VEVENT