SUMMARY:Nonlinear structural analysis of the Victor-Neels suspension foot
 bridge under large amplitude vibrations
LOCATION:Room B302
DESCRIPTION:MS 07\n\nPresenter: Zeoli\, Juliette\n\nAuthors: Zeoli\, Juli
 ette\n\nChair: Van den Broeck\, Peter \n\nAbstract: Nonlinear structural
  analysis of the Victor-Neels suspension footbridge under large amplitud
 e vibrations   Juliette Zeoli^{a}\, Vincent Denoël^{a}  ^{a} Structural 
 & Stochastic Dynamics\, University of Liège     ABSTRACT. This paper exa
 mines the dynamic behaviour of a suspended pedestrian bridge\, with emph
 asis on the geometric nonlinearities arising from the quadratic relation
 ship between cable stiffness and displacement. The Victor-Neels bridge b
 uilt in Eiffel (Germany) served as a case study. A detailed numerical mo
 del was developed using in in-house nonlinear finite element model and c
 alibrated through an experimental campaign involving pedestrian-induced 
 vibrations. Modal parameters were identified\, and hanger tension measur
 ements enabled refinement of the model to accurately reproduce the actua
 l behaviour of the bridge.  Nonlinear dynamic numerical analyses conduct
 ed with a set of sine-sweep excitations of varying amplitude revealed a 
 stiffness increase beyond a certain vibration threshold\, leading to sma
 ller displacement amplitudes and a shift in the resonant frequency compa
 red to linear predictions. Although linear analyses tend to be conservat
 ive\, they may overestimate displacements and encourage unnecessary stru
 ctural measures such as oversized designs or Tuned Mass Dampers (TMDs). 
  The study further assessed the performance of linear TMDs under both li
 near and nonlinear conditions. When tuned to the shifted frequency obtai
 ned from nonlinear analysis\, TMD efficiency improved\, allowing compara
 ble damping performance with a reduced mass. These findings open perspec
 tives for optimizing TMD design and for developing nonlinear TMDs featur
 ing speed-dependent damping to further mitigate vibration amplitudes.