UID:102@eurodyn2026.org
DTSTAMP:20261026T144037Z
DTSTART;TZID=Europe/Berlin:20260928T125000
DTEND;TZID=Europe/Berlin:20260928T131000
SUMMARY:Analytical and Experimental Study of a Tuned Liquid Column Damper
  Integrated with Flexible Membranes
LOCATION:Room F303
DESCRIPTION:MS 23\n\nPresenter: Di Matteo\, Alberto\n\nAuthors: Di Matteo
 \, Alberto\; Pirrotta\, Antonina\n\nChair: Di Matteo\, Alberto\n\nAbstra
 ct: This study investigates the vibration control performance of structu
 res equipped with a novel Tuned Liquid Column Damper (TLCD) integrated w
 ith flexible elastomer membranes. The system combines the passive dampin
 g characteristics of a TLCD with the adaptive properties of deformable m
 embranes\, enabling enhanced vibration suppression under dynamic loading
 . A comprehensive mathematical model is developed to capture the coupled
  interaction among the liquid motion\, the membrane’s hyperelastic respo
 nse\, and the thermodynamic behavior of the enclosed air volume. A simpl
 ified analytical formulation is derived to predict the steady-state resp
 onse of the coupled structure–damper system using a harmonic balance app
 roach. Numerical simulations and experimental validation under harmonic 
 and broadband excitations demonstrate strong agreement and confirm the a
 ccuracy of the analytical model. The results show that the integration o
 f flexible membranes significantly improves vibration attenuation\, broa
 dens the eHective damping bandwidth\, and allows for tunability of the c
 ontrol performance. Compared with conventional TLCDs\, the proposed TLCD
 –membrane system exhibits superior adaptability in mitigating structural
  vibrations. These findings highlight the potential of hybrid fluid–memb
 rane devices for advanced vibration control in civil and mechanical stru
 ctures\, including tall buildings\, wind turbines\, and oHshore platform
 s.
URL:https://eurodyn2026.org/submission/102
END:VEVENT