BEGIN:VEVENT
UID:93@eurodyn2026.org
DTSTAMP:20261026T144037Z
DTSTART;TZID=Europe/Berlin:20260928T123000
DTEND;TZID=Europe/Berlin:20260928T125000
SUMMARY:Inerter-based vibration control devices with Rhombic Configuratio
 n for Apparent Mass Amplification
LOCATION:Room F303
DESCRIPTION:MS 23\n\nPresenter: Di Nardo\, Leonardo Adam\n\nAuthors: Di N
 ardo\, Leonardo Adam\; Masnata\, Chiara\; Pirrotta\, Antonina\n\nChair: 
 Di Matteo\, Alberto\n\nAbstract: Inerter-based devices are increasingly 
 investigated for vibration control in dynamic systems\, where increasing
  apparent mass can enhance structural response mitigation without a sign
 ificant increase in physical weight. This work examines the dynamic beha
 vior and experimental characterization of a mechanical inerter integrate
 d within a rhombic frame\, exploiting geometric amplification to boost e
 ffective inertance. The device combines a traditional inerter mechanism 
 with a truss-like rhombic arrangement\, allowing the inertial forces to 
 be amplified through the kinematic properties of the frame. Such amplifi
 cation is particularly advantageous when the device interacts with secon
 dary systems\, enhancing overall vibration suppression. The study focuse
 s on the relationship between the rhombic geometry and the measured iner
 tance\, emphasizing discrepancies observed between classical theoretical
  predictions and experimental results. Harmonic excitation tests are con
 ducted to evaluate frequency-dependent behavior and refine analytical fo
 rmulations of the inertial response. Results demonstrate that embedding 
 the inerter in a rhombic frame effectively amplifies the apparent mass\,
  while highlighting nonlinearities and experimental uncertainties that c
 omplicate inertance estimation. These findings provide insights for the 
 design and modeling of inerter-based vibration control devices in struct
 ural systems\, showing the potential of geometric amplification for enha
 nced performance.
URL:https://eurodyn2026.org/submission/93