BEGIN:VEVENT
UID:252@eurodyn2026.org
DTSTAMP:20261026T144037Z
DTSTART;TZID=Europe/Berlin:20260928T121000
DTEND;TZID=Europe/Berlin:20260928T123000
SUMMARY:Experimental Characterization of Downburst Wind Loads on Bridge D
 ecks
LOCATION:Room F128
DESCRIPTION:MS 20\n\nPresenter: Petersen\, Øyvind\n\nAuthors: Petersen\, 
 Øyvind\; Hansen\, Sebastian Knedahl\; Øiseth\, Ole\; Fenerci\, Aksel\n\n
 Chair: Borri\, Claudio\n\nAbstract: For long-span bridges\, wind is amon
 g the most critical loads influencing design. While conventional bridge 
 aerodynamics has largely focused on synoptic wind conditions associated 
 with large-scale weather systems\, increasing attention is being directe
 d toward non-synoptic wind events such as downbursts.  Downbursts\, char
 acterized by intense localized outflows generated by convective storms\,
  have in recent years been observed to cause significant responses on lo
 ng-span bridges\, motivating further studies to understand their influen
 ce.  This study presents results from wind-tunnel experiments conducted 
 at the WindEEE Dome\, where transient downburst-like flows were applied 
 to a bridge section model at a geometric scale of 1:100. Two types of te
 sts were performed: (i) a static pressure model instrumented with pressu
 re taps to capture distributed load fields\, including spanwise correlat
 ions\; and (ii) a dynamic mass–spring section model with three degrees o
 f freedom to measure responses induced by non-stationary aerodynamic loa
 ds. Each downburst event was repeated eight times under varying test con
 figurations\, including different bridge heights above ground and latera
 l offsets between the downburst centre and the bridge deck.  We examine 
 the repeatability of the experiments and characterize the pressure loads
  in terms of the downburst front build-up and subsequent turbulent phase
 . Based on these results\, simple non-stationary load models using time-
 varying mean wind velocities and turbulence intensities are proposed for
  simulating downburst-induced responses of super-long-span bridges. The 
 findings contribute to ongoing efforts to integrate non-synoptic wind ef
 fects into bridge design practice.
URL:https://eurodyn2026.org/submission/252